Описание

Controller
Model IM-7000*1
Type Controller
Image sensor 1” 6.6 mega pixel monochrome CMOS
Display 10. 4” LCD monitor (XGA: 1024 ? 768)
Receiver lens Double telecentric lens
Image measurement Field of view Wide-field measurement mode: 200 mm ? 200 mm (4 ? R50) High-precision measurement mode: 125 ? 125 mm
Minimum display unit 0.1 µm
Repeatability W/o stage movement Wide-field measurement mode: ±1 µm High-precision measurement mode: ±0.5 µm
With stage movement Wide-field measurement mode: ±2 µm High-precision measurement mode: ±1.5 µm
Measurement accuracy (±2?) W/o binding Wide-field measurement mode: ±5 µm*2 High-precision measurement mode: ±2 µm*3
With binding Wide-field measurement mode: ± (7 + 0.02 L) µm*4 High-precision measurement mode: ± (4 + 0.02L) µm*5
Light probe Measurement Measurable area (XY) 90 ? 90 mm
Maximum measurement depth 30 mm
Light probe diameter o3 mm
Measuring force 0.015 N
Repeatability ±2 µm*6
Measurement accuracy ± (8 + 0.02 L) µm*7
External remote input Non-voltage input (with and without contact)
External output OK/NG/FAIL/MEAS. PhotoMos output Rated load 24 VDC 0.5 A ON resistance 50 m? or lower
Interface LAN RJ-45 (10BASE-T/100BASE-TX/1000BASE-T)
USB 2.0 series A 6 ports (front: 2, rear: 4)
Record Hard disk drive 500 GB
Illumination system Transparent Telecentric transparent illumination
Ring Four division ring illumination (IM-7010) Four division, multi-angle illumination (electric), Slit ring (directivity) illumination (electric) (IM-7020)
XY stage Moving range 100 ? 100 mm (electric)
Withstand load 5 kg
Z stage Moving range 75 mm (electric)
Power supply Power voltage 100 to 240 VAC 50/60 Hz
Power consumption 430 VA or lower
Environmental resistance Pollution degree 2
Overvoltage category II
Ambient temperature +10 to +35 °C
Relative humidity 20 to 80 % RH (No condensation)
Weight Approx. 8 kg
*1 Light probe measurement (IM-7020 only) *2 In the range of o80 mm, within the operating ambient temperature range of +23°C ±1°C at the focused focal point position *3 In the range of o20 mm within the operating ambient temperature range of +23°C ±1°C at the focused focal point position *4 In the range of 180 ? 180 mm (4 ? R40), within the operating ambient temperature range of +23°C ±1°C at the focused focal point position, and with a load weighing 2 kg or less on the stage (L = amount of stage movement in mm units) *5 In the range of 120 ? 120 mm, within the operating ambient temperature range of +23°C ±1°C at the focused focal point position, and with a load weighing 2 kg or less on the stage (L = amount of stage movement in mm units) *6 When the detection system is standard. If the detection system is at a deep position, then ±3 µm *7 When the detection system is standard, and the ambient temperature is 23°C ±1°C, with a stage load weighing 2 kg or less. If the detection system is at a deep position, then ± (10 + 0.02 L) µm with L as the measurement length in mm.
''