Описание

  • Auxiliary release on the front
  • Two LED indicators, red and green
  • Plug connector SR6
  • Actuating head fitted right
Approach direction Horizontal Can be adjusted in 90° steps Solenoid operating voltage and LED function display
  • 110 V AC -15%, +10%
Guard locking type
TZ2Open-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force.
Switching element
SKFor monitoring the door/actuator position
UKFor monitoring the guard locking (built-in solenoid)
528HSlow-action switching contact 1 NC + 1 NO
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. Sealing can be fitted to protect against tampering. Lead seal kit and tool included (already pre-assembled on versions with plug connectors).
Housing material Anodized die-cast alloy
Weight
Net 1,2 kg
Ambient temperature -25 ... 80 °C
Degree of protection IP65
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 1
Number of door position NO contacts 1
Number of guard lock monitoring positively driven contacts 1
Number of guard lock monitoring NO contacts 1
Connection
1 x Plug connector SR6
Approach speed max.20 m/min
Actuation frequency 1200 1/h
Guard locking principle Open-circuit current principle
Locking force Fmax 2000 N
Locking force FZh 1500 N
Retention force 10 N
Extraction force 30 N
Actuating force 35 N
Insertion depth min.52 mm
Cover lid Black
Electrical connection ratings
Thermal rated current Ith 4 A 70°C => 2A'>
Utilization category according to EN 60947-5-1
AC-15 4A 230V 70°C => 2A'>
DC-13 4A 24V 70°C => 2A'>
Solenoid operating voltage
AC 110 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG 70°C => 2A gG'>
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 10 W
Solenoid duty cycle 100 %
LED indicator Operating voltage corresponds to the solenoid voltage
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
B10D 3 x 106
In combination with Actuator BETAETIGER-Z-GNMechanical values and environment
Overtravel 16 mm
In combination with Actuator BETAETIGER-Z-GMechanical values and environment
Overtravel 4 mm
''