Описание

  • Auxiliary release on the front
  • With door monitoring contact
Approach direction Horizontal and vertical Can be adjusted in 90° steps Solenoid operating voltage
  • AC/DC 24 V +10%, -15%
LED function displayThe switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage. Guard locking type
TX1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
Switching element
ETX BSlow-action switching contact 2 NC / 1 NO + 1 NC (door monitoring contact)
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).
Housing material Die-cast alloy, cathodically dipped
Weight
Net 0,8 kg
Ambient temperature -20 ... 80 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position NC contacts 1
Number of guard lock monitoring positively driven contacts 2
Number of guard lock monitoring NO contacts 1
Connection
3 x M20 x 1.5
Approach speed
max. 20 m/min
Actuation frequency 1200 1/h
Guard locking principle Closed-circuit current principle
Locking force Fmax 1700 N
Locking force FZh 1300 N
Retention force 20 N
Extraction force 35 N
Actuating force 35 N
Insertion depth min.32 mm
Electrical connection ratings
Thermal rated current Ith 4 A
Utilization category according to EN 60947-5-1
AC-15 4A 230V
DC-13 4A 24V
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 8 W
Solenoid duty cycle 100 %
Connection cross-section 0,34 ... 1,5 mm?
LED indicator Operating voltage corresponds to the solenoid voltage
Reliability values according to EN ISO 13849-1
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Monitoring of guard locking and the safety guard position
B10D 6 x 106
In combination with Actuator BETAETIGER-X-GQMechanical values and environment
Overtravel 1 mm
In combination with Actuator BETAETIGER-X-GNQMechanical values and environment
Overtravel 8 mm
''